Unit Allocation

4.1.3 Registration in I/O Map

Before setting parameters, register the unit to be used in the I/O map. The following
procedure shows an example when FPWIN GR7 has been started and the CPU unit has been
already registered as the slot number 0 and the multi I/O unit is allocated to the slot number 1.
PROCEDURE
1. Select "Options" > "FP7 Configuration" > "I/O map" in the menu bar.
The "I/O map" dialog box will be displayed.
2. Double-click a desired slot.
The "Unit selection" dialog box is displayed.
3. Select the unit name used in the field of "Select unit to use", and press the
"OK" button.
The selected unit is now registered in the I/O map.
The following figure shows the case that the input and output units have been
registered subsequently. The multi I/O unit occupies four words each for input and
output.
4-4