Positioning Function (H type)

10.13 Operational Difference Between Speed Parameters

10.13.1

Startup Speed

• The startup speed is the parameter for setting the initial speed when starting each operation
and the speed when finishing each operation.
• The startup speed is common to each control of the JOG operation, home return, E-point
control, P-point control, C-point control and J-point control operations. It is set for each
channel number (axis number).
 Setting method of startup speed
It is set in the "Parameter settings" dialog box of Configurator PMX.
 Precautions when setting the startup speed
• The home return creep speed setting is not influenced by the startup speed in the home
return operation.
• The target speed of each operation is not influenced by the startup speed. Each operation is
performed at each specified target speed regardless of the setting of startup speed.
10-70