Positioning Function (H type)
 Connection example using push-pull negative logic output
Controller
FP7 MXY32DWDH
I/O
no.
Y8
CW pulse
command output
Y9
CCW pulse
command output
X0
Home input
COM
0
Step-
Output circuit
+
down
driving power
circuit
supply
Y4
Deviaton counter
clear output
COM
0
Near home input
X1
Over limit input (-)
X3
Over limit input (+)
X2
Near home sensor
CCW limit sensor
CW limit sensor
(Note): The allocation of I/O numbers on the controller side depends on the setting condition of the unit.
10-6
* The processing of shielded wires varies
Terminal
depending on each device.
no.
2 kΩ
B11
2 kΩ
B12
A1
A9
A19
B19
A15
A20
B20
A9
A2
A4
A3
+24 V
GND
24 V DC
power supply
A5II, A5IIE, A5, A5E series
50
FG
3
PULS1
PULS2
4
5
SIGN1
6
SIGN2
19
CZ
GND
13
GND
25
7
COM+
30
CL
29
SRV-ON
27
GAIN
From PLC
31
A-CLR
I/O output
9
POT
8
NOT
S-RDY+
35
34
S-RDY−
To PLC
37
ALM+
I/O input
36
ALM−
39
INP+
38
INP−
41
COM−
Amplifier
Command pulse input 2
220 Ω
Command sign input 2
220 Ω
Z phase input
4.7 kΩ
Counter clear input
4.7 kΩ
Servo on input
4.7 kΩ
Gain swich input
4.7 kΩ
Alarm clear input
4.7 kΩ
CW over-travel
inhibit input
4.7 kΩ
CCW over-travel
inhibit input
Servo ready output
Servo alarm output
Positioning done output