Pulse Output / PWM Output Function

9.4.3 Setting Example of Pulse Output (Comparison Match Stop)

 Overview
The pulse output is performed in the individual output mode. It is controlled by the switch input
(X140/X141) connected to the 32-point input unit. If the start input (X141) turns on when the
enable input (X140) is on, the pulse output will start. When the value of the pulse output
counter reaches the comparison output setting value, the pulse will stop.
0 V (24 V DC)
(PLS0 EN)
X140
(PLS0 ST)
X141
 Configuration
• Set the pulse output to the outputs (Y108-Y109).
• Select "PLS output - Comparison match stop" in the "Pulse output Advanced " dialog box,
and input a frequency.
• Select "When start signal rises" for the data update timing.
• Select "Comparison match output" in the "Selection of function" tree, and double-click the
comparison match number CMP0 to open the "Advanced" dialog box.
• In the advanced setting dialog box, select "Pulse output PLS0", "ON when elapsed value is
larger than or equal to setting value", and input a comparison value.
9-16
Multi I/O Unit
WX10-WX13
WX14
WY10-WY13
32-point Input Unit
Y108 (PLS0 A)
Y109 (PLS0 B)
Y100 (CMP0)
Y118 (PLS0 EN)
Y11C (PLS0 ST)