10.10.6

J-point Control (JOG Positioning: Speed Changes)

• In the J-point control, the speed can be changed while controlling the speed after the start.
• After starting the J-point control, the unit operates at the speed specified in the positioning
parameters of Configurator PMX.
• The speed changes when the J-point control speed change flag (Y54, Y55) turns on.
• For J-point control, only "Increment" can be used as a control method.
 Operation diagram
f (Hz]
20,000Hz
15,000Hz
10,000Hz
1,000Hz
Instruction start condition
Busy signal
Operation done signal
J point control
speed change
J point control
positioning start input
 Operations of each contact
• The BUSY flags (X30, X31) will turn on when the operation starts and turn off when the
operation is completed.
• The operation done flags (X34, X35) will turn on when the JOG operation is completed, and
it will be held until the next positiotning control, JOG operation, or home return operation
starts.
• The target speed will be changed when the J-point control speed change flags (Y54, Y55)
turn on. The change will be enabled at the edge where the contact turns on.
• Positioning control will start when J-point control positioning start inputs (X1, X5 or Y50, Y51)
turn on. However, when the inputs (X1, X5) are used as near home inputs, J-point control
will not be performed.
J-point speed change
Table 1
100ms
Approx. 50 ms
10.10 Positioning Control
Table 2
100000
pulses
150 ms
250ms
t [ms]
50ms
10-57