Peak-to-Peak Ripple
深圳市盛腾仪器仪表有限公司
1.
This limit test requires that you first define a segment on the measurement
trace using markers 1 and 2 (or markers 3 and 4 for measurement
channel 2). Then press @iGZK] Mmk&r F~c%ions Mwksr Et&t&
Statistics to enable the statistics marker search. See "To Use Marker
Statistics" earlier in this chapter for more information on using marker
statistics.
2.
Press fjj] Limit; MGZIIU
3.
Use the front panel knob or the @) (IJJ keys to select Statistic : p-p in
the marker limit test table. Turn this limit function on by pressing the
table changes to "on."
4.
Press Edit Limit (Min&ax) Max Limiz and enter the maximum
limit using the front panel keypad and terminating the entry with the
k e y .
5.
Press Edi% Limit CMinfHax) Nin Limf% and enter the minimum limit
using the front panel keypad and terminating the entry with the (ENTER)
key.
N O T E
Note that there are no visible limit lines or indicators on the display with this limit test function.
Therefore the
Limit Line
Tel:0755-83589391
Mkr
Limits .
OFF
function has no effect when using marker limits.