Security and authentication
11.7 Port Based Network Access Control
Requirement
You are in the User EXEC mode or in the Privileged EXEC mode.
The command prompt is as follows:
cli>
Syntax
Call up the command with the following parameters:
show dot1x[{interface<interface-type><interface-id>|
The parameters have the following meaning:
Parameter
interface
interface-type
interface-id
statistics inter-
face
interface-type
interface-id
For information on names of addresses and interfaces, refer to the section "Interface
identifiers and addresses (Page 39)".
Result
The dot1x information is displayed.
11.7.1.2
show dot1x guest-vlan mac-info
Description
This command displays which MAC address and which port are assigned to a guest VLAN.
Requirement
You are in the User EXEC mode or in the Privileged EXEC mode.
The command prompt is as follows:
cli>
Syntax
Call the command without parameters:
show dot1x guest-vlan mac-info
742
or
cli#
statistics interface<interface-type><interface-id>}]
Description
Keyword for a an interface description
Type or speed of the interface
Module no. and port no. of the interface
Keyword for the display of the statisti-
cal data of the dot1x Authenticator for
an interface
Type or speed of the interface
Module no. and port no. of the interface
or
cli#
Range of values / note
-
Enter a valid interface.
-
Enter a valid interface.
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 11/2015, C79000-G8976-C252-10