Syntax
Call up the command with the following parameters:
no ip route <prefix> <mask> <next-hop> [<distance(1-255)>]
The parameter has the following meaning:
Parameter
prefix
mask
next-hop
distance
For information on names of addresses and interfaces, refer to the section "Interface
identifiers and addresses (Page 39)".
Result
The entry is deleted.
Further notes
You configure an entry from the IP routing table with the
You display the IP routing table with the
7.1.2.3

ip routing

Description
With this command, you enable the routing function for IPv4.
Note
This command is available only with layer 3. DHCP must not be enabled on any IP interface.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 11/2015, C79000-G8976-C252-10
Description
Specifies the IP address or the address
range
Specifies the subnet mask used for
.
prefix
Use decimal notation.
specifies the IP address to which the
selected addresses were forwarded.
The value for the administrative dis-
tance.
show ip route
Network protocols
7.1 IPv4 protocol
Range of values / note
specify a valid IP address
enter a valid subnet mask
specify a valid IP address
1 ... 255
command.
ip route
command.