2.7.5.3

Completion of command entries

Description
The command interpreter of the Command Line Interface supports you when you enter
commands.
As soon as the first characters of the command have been entered in the input line, the
system can complete the entry as long as the character string is unambiguous.
This can be repeated after entering further characters.
Procedure
Enter the first characters of the command.
Press the tab key.
Result
The command interpreter completes the input as long as the command is unambiguous.
If you enter a character string that cannot be completed to form a command, an error
message is displayed.
● The command is not unique:
● The command is unknown:
● The command is incomplete:
If the entry is not yet complete, enter further characters.
With
Repeat this if necessary until the command is complete and can execute.
2.7.5.4

Abbreviated notation of commands

Description
The command interpreter of the Command Line Interface also detects commands if only the
first character of the command or its parts is entered.
This is only possible if all the parts of the abbreviated input can be assigned to exactly one
command or to the parts of the command.
Example
The
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 11/2015, C79000-G8976-C252-10
, you obtain a list of the possible commands.
?
command can be replaced by the expression
show event config
% Ambiguous Command
% Invalid Command
% Incomplete command
Description
2.7 General CLI commands
.
sh e c
53