Network protocols
7.7 SNMP
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
snmp notify <NotifyName> tag <TagName> type {Trap|Inform}
[{volatile|nonvolatile}]]
The parameters have the following meaning:
Parameter
NotifyName
tag
TagName
Type
Storage type
Result
The details of the SNMP notifications are configured.
Further notes
You delete the details of an SNMP group with the
You display the configured SNMP notifications with the
You display the configured SNMP target addresses with the
command.
7.7.2.11

no snmp notify

Description
With this command, you delete the details of the SNMP notifications.
356
Description
Name of the SNMP notification
Keyword for a target key
Name of the target key
Type of the SNMP notification
specifies whether the settings remain
following a restart:
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Range of values / note
max. 32 characters
-
max. 32 characters
Trap
generates a trap
Inform
generates a log entry or sends
an entry to the log server
volatile
The settings are lost after a
restart
nonvolatile
The settings are retained after
a restart
command.
no snmp notify
show snmp notif
show snmp targetaddr
Configuration Manual, 11/2015, C79000-G8976-C252-10
(volatile):
(non-volatile):
command.