Time Set - Siemens SCALANCE XM-400 Configuration Manual

Industrial ethernet switches
Hide thumbs Also See for SCALANCE XM-400:
Table of Contents

Advertisement

Syntax
Call up the command with the following parameters:
time{manual | ntp | sntp | SINEC | ptp_tc_client}
The parameters have the following meaning:
Parameter
manual
ntp
sntp
SINEC
ptp_tc_client
Result
The method of obtaining the system time is configured.
Further notes
You display the settings for the system clock with the
5.1.2.2

time set

Description
With this command, you set the system clock.
Requirement
You are in the Global Configuration mode.
The command prompt is as follows:
cli(config)#
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 11/2015, C79000-G8976-C252-10
Description
The system time is entered by the user.
The system time is obtained from an NTP server.
The system time is obtained from an SNTP server.
The system time is obtained using the SIMATIC time
protocol .
The system time is obtained with the Precision Time
Protocol (PTP) from a grandmaster clock.
5.1 System time setting
Range of values / note
-
-
-
-
The following devices
support time-of-day
synchronization using
PTP:
SCALANCE XR528-
6M
SCALANCE XR552-
12M
command.
show time
System time
147

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Scalance xr-500

Table of Contents