Commands In The Events Configuration Mode; Add Log - Siemens SCALANCE XM-400 Configuration Manual

Industrial ethernet switches
Hide thumbs Also See for SCALANCE XM-400:
Table of Contents

Advertisement

Syntax
Call up the command without parameters or with the following parameter assignment:
cabletest interface <interface-type> <interface-id> [force]
The parameters have the following meaning:
Parameter
interface-type
interface-id
force
For information on names of addresses and interfaces, refer to the section "Interface
identifiers and addresses (Page 39)".
If you do not select any parameters from the parameter list, the default value is used.
Result
Following the test phase, the result is displayed.
The value for the distance has a tolerance of +/- 1 m.
12.1.6

Commands in the Events configuration mode

This section describes commands that you can call up in the EVENTS configuration mode.
In the Global configuration mode, enter the
Commands relating to other topics that can be called in the Global configuration mode can
be found in the relevant sections.
● If you exit the EVENTS configuration mode with the
Global configuration mode.
● If you exit the EVENTS configuration mode with the
Privileged EXEC mode.
12.1.6.1

add log

Description
With this command, you create an entry in the log.
Requirement
You are in the EVENTS Configuration mode.
The command prompt is as follows:
cli(config-events)#
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 11/2015, C79000-G8976-C252-10
Description
Type of interface
Interface identifier
Forces a
during the test
link down
events
12.1 Event and fault handling
Range of values / note
Enter a valid interface.
Necessary parameter if there is a
on the interface.
link up
command to change to this mode.
command, you return to the
exit
command, you return to the
end
Diagnostics