5-19 Setting the PF Key

5-19-1 PF Setting (Function Key)

PF Setting (Advanced
Function Setting Level)
pf
shft
Set value
Display
off
OFF
run
RUN
rst
RST
r-r
R-R
hold
HOLD
at-2
AT-2
at-1
AT-1
ata2
ATA2
ata1
ATA1
lat
LAT
a-m
A-M
pfdp
PFDP
shft
SHFT
*1
When AT cancel is specified, it means that autotuning is canceled regardless of the type of autotuning that is
currently being executed.
*2
Alarms 1 to 4, the HB alarm, and the HS alarm are cancelled.
*3
For details on auto/manual operations using the PF Key, refer to 5-11 Performing Manual Control.
*4
AT-1 or ATA1 can be set for heating/cooling control or floating position-proportional control, but the function is
disabled.
Note1: Pressing the PF Key for at least one second executes operation according to the set value.
(However, if Digit Shift is set, operation will be in less than one second.) When the Monitor/Setting
Item parameter is selected, however, the display is changed in order from Monitor/Setting Item 1 to 5
each time the key is pressed.
2: This function is enabled when PF Key Protect is OFF.
5 - 74
• Pressing the PF Key for at least one second executes the operation set in the
PF Setting parameter. The default is shft (digit shift).
Setting
Disabled
Does not operate as a function key.
RUN
Specifies RUN status.
Reset
Specifies resetting.
Run/Reset
Specifies reversing operation status between Run and
Reset.
Hold/Clear Hold
Specifies reversing operation status between Hold and Hold
Clear.
100% AT
Specifies reversing the 100% AT Execute/Cancel status.*1
Execute/Cancel
40% AT
Specifies reversing the 40% AT Execute/Cancel status.*1 *4
Execute/Cancel
All PID 100% AT Exe-
Specifies reversing 100% AT execute/cancel status for all
cute/Cancel
PID sets.*1
All PID 40% AT Exe-
Specifies reversing 40% AT execute/cancel status for all PID
cute/Cancel
sets.*1*4
Alarm Latch Cancel
Specifies canceling all alarm latches.*2
Auto/Manual
Specifies reversing the Auto/Manual status.*3
Monitor/Setting Item
Specifies the monitor/setting item display. Select the monitor
setting item according to the Monitor/Setting Item 1 to 5
parameters (Advanced Function Setting Level).
Operates as a Digit Shift Key when settings are being
Digit Shift
changed.
Function
E5@C-T Digital Temperature Controllers User's Manual (H185)