5 Advanced Operations
Program 0 time signal parameter
Time Signal 1 Set Segment
Time Signal 1 ON Time
Time Signal 1 OFF Time
Time Signal 2 Set Segment
Time Signal 2 ON Time
Time Signal 2 OFF Time
Note: It is assumed that the time signals are already assigned to control outputs or auxiliary outputs.
5
Click the Graph Display Button in the upper right corner of the Programmer Editor.
The same program pattern as given for the step time programming example will be displayed.
Transferring the Set Program to the Digital Controller
You must transfer the data for the program settings to the Digital Controller. Refer to CX-Thermo help
from the Help Menu for the procedure to transfer the settings.
Copying a Set Program to Another Program Number
You can specify the source and destination program numbers and click the Copy Program Button to
easily copy a set program to another program number
1
Specify the source program
number.
5 - 100
Set value
2
0 min.
1 min.
3
0 min.
1 min.
2
Specify the destination
program number.
3
Click the Copy Program
Button.