Omron E5AC-T User Manual page 428

E5xc-t series digital temperature controllers programmable type
Hide thumbs Also See for E5AC-T:
Table of Contents

Advertisement

Press O + M Key
for at least 3 s.
Press O + M Key for at least 3 s. (The key pressing
time can be changed in the Move to Protect Level
Time parameter (Advanced Function Setting Level).)
Press O + M Key for at least 1 s.
Initial Setting Level
Press O Key
for at least 3 s.
in-t
Input Type
5
M
Press O Key
Scaling Upper Limit
in-h
for at least 1 s.
100
M
Scaling Lower Limit
in-l
Press O Key
for at least 3 s.
0
M
Decimal Point
dp
0
M
d-u
Temperature
Unit
c
M
sl-h
SP Upper Limit
1300
M
of-r
Manual Reset Value
50.0
M
hys
Hysteresis (Heating)
1.0
M
chys
Hysteresis (Cooling)
1.0
M
mv-r
MV at Reset
0.0
M
mv-e
MV at PV Error
0.0
M
ol-h
MV Upper Limit
100.0
M
ol-l
MV Lower Limit
0.0
M
E5@C-T Digital Temperature Controllers User's Manual (H185)
Protect Level
Operation/Adjustment
M
oapt
pmov
Protect
0
0
M
Move to Protect Level
Initial Setting/
icpt
Communications Protect
1
M
Setting Change Protect
wtpt
off
M
sl-l
SP Lower Limit
eset
Operation End
Operation
-200
rst
M
M
t-u
pvst
Program Time Unit
PV Start
h-m
sp
M
M
t-pr
tspu
Step Time/Rate of
All PID AT Upper
Rise Programming
Limit SP
time
0
M
M
pru
cntl
PID ON/OFF
Time Unit of Ramp
Rate
pid
m
M
M
Standard or
rtsm
s-hc
Reset Operation
Heating/Cooling
stop
stnd
M
M
Control Period
p-on
cp
Startup Operation
(Heating)
cont
20
M
M
orl
MV Change Rate
Limit
0.0
M
db
Position Proportional
Dead Band
2.0
M
oc-h
Open/Close
Hysteresis
0.8
M
sqrp
Extraction of Square
Root Low-cut Point
0.0
M
w1on
Work Bit 1 to 8 ON
Delay
0
M
w1of
Work Bit 1 to 8 OFF
Delay
0
M
plcm
Communications
Monitor
0
M
pfpt
PF Key Protect
off
M
Parameter Mask Enable
pmsk
on
M
Password to Move
prlp
to Protect Level
0
M
Control Period
c-cp
tr-t
Transfer Output
(Cooling)
Type
20
off
M
M
Direct/Reverse
orev
tr-h
Transfer Output
Operation
Upper Limit
or-r
100.0
M
M
alt1
tr-l
Transfer Output
Alarm 1 to 4
Lower Limit
Type
2
0.0
M
M
alh1
Alarm 1 to 4
ev-1
Event Input
Hysteresis
0.2
Assignment 1
rr-1
M
M
o1st
Control output
ev-2
Event Input
1 to 2 Signal
Assignment 2
4-20
adv
M
M
ev-3
Event Input
trst
Transfer Output
Assignment 3
Signal
4-20
none
to 6
M
M
clfl
Close/Floating
flot
M
Press O Key for less than 1 s.
Communications Setting Level
psel
sdwt
Send Data
Protocol Setting
Wait Time
cwf
20
M
M
Highest
Communications
maxu
u-no
Communications
Unit No.
1
0
Unit No.
M
M
bps
Communications
area
Area
Baud Rate
9.6
0
M
M
First Address
adrh
len
Communications
Upper Word
Data Length
0
7
M
M
First Address
adrl
sbit
Communications
Lower Word
Stop Bits
0
2
M
M
Receive Data
Communications
rwat
prty
Wait Time
Parity
1000
even
M
M
Models with communications only: Changes to settings are applied
when the power is cycled or a software reset is performed.
*1 When PF Setting = A-M.
*2 When PF Setting = PFDP.
A Appendices
Press O Key
for at least 1 s.
calb
Motor Calibration
off
M
mot
Travel Time
30
M
vl-c
Valve Completely
Closed Position
0
M
vl-o
Valve Completely
Open Position
9999
M
pms
Potentiometer
Specification Setting
0
M
sqr
Extraction of
Square Root
off
Enable
M
amov
Moves to Advanced
Function Setting
0
Level
Enter password (−169)
M
to move.
A
unit
Communications
Node Number
0
M
up 1
Upload
Setting
0
1 to 23
M
dn 1
Download
0
Setting
1 to 43
M
copy
Copy
off
M
M
A - 39