Item
Part Number
1
2
3
10653
4
5
6
5. Engage the remote starter switch. Read and record the voltage. The voltage reading should be
0.5 volt or less.
6. If the voltage reading is less than 0.5 volts, go to the Starter Motor-Ground Circuit Component
Test.
7. If the voltage reading is greater than 0.5 volts, this an indication of excessive resistance in the
connections, the positive battery cable or in the starter solenoid. Move the Digital Multimeter
negative lead to the starter solenoid B-terminal and repeat the test. If the voltage reading at the
B-terminal is less than 0.5 volts, the concern is either in the connections at the starter solenoid
or in the solenoid contacts. Go to Step 8. If the voltage reading is greater than 0.5 volts at the B-
terminal, the concern is either the positive battery cable or connections. Go to Step 9.
Item
Part Number
1
2
3
10653
4
5
6
8. Remove the cables from solenoid B-, S- and M-terminals. Clean the cables and connections
and reinstall the cables to the correct terminals. Repeat Steps 3 through 6. If the voltage drop
Description
S-terminal
Remote starter switch
Battery
Digital multimeter
B-terminal
M-terminal
Description
S-terminal
Remote starter switch
Battery
Digital multimeter
B-terminal
M-terminal