SECTION 303-04B: Fuel Charging and Controls — 4.6L (2V)
REMOVAL AND INSTALLATION
Fuel Charging Wiring Harness
Removal
WARNING: Do not smoke or carry lighted tobacco or open flame of any type when
working on or near any fuel related components. Highly flammable mixtures are always present
and may be ignited. Failure to follow these instructions may result in personal injury.
1. Disconnect the battery ground cable (14301). For additional information, refer to
01
.
2. Disconnect the air cleaner outlet tube. For additional information, refer to
3. Disconnect the 42 pin connector.
4. Separate the wiring harness retainers from the dash panel.
5. Disconnect the following connectors:
Throttle position (TP) sensor
Idle air control (IAC) valve