Emulation Module Error - SATO S84ex Operator's Manual

Hide thumbs Also See for S84ex:
Table of Contents

Advertisement

VERIFYING... XX/XX
The printer is verifying the module data.
The bar on the lower portion of the screen indicates the data verification
progress.
XX/XX shows the file number being read and total number of files.
After verifying the module data, it goes to the MODULE DOWNLOAD
COMPLETED screen.
Note
Shows only if INTERFACE SELECT is set to SD CARD or USB MEMORY.
5.1.4

Emulation Module Error

If error occurred during module loading or deleting process,
the screen shows the error massage, MODULE ERROR
and the cause of the error as listed below.
• READ DATA ERR
• WRITE DATA ERR
• VERIFY DATA ERR
• WRONG HEADER
• WRONG CHECKSUM
When read data error, write data error or verify data error
occurred, update the emulation loader firmware or change
the FLASH ROM device.
When wrong header or wrong checksum error occurred,
delete the emulation module and then download the
emulation module firmware again.
If error occurred during module downloading, the screen
shows the error massage, DOWNLOAD DATA ERROR.
The possible causes of module download error are:
• Module header error.
• Not enough memory space or the module size is too big.
When the module download error occurred,
• Check the module header information.
• Delete the old module.
• Delete the unused module.