READ POWER
Set the read power of the antenna, referring to the "S84-ex UHF Inlay
Placement & Configuration Table" in the S84-ex UHF RFID Configuration
Guide.
The measurement unit is in dBm, and it is adjustable with 0.1 dBm.
The value converted to milliwatts (mW) is shown on the left.
The setting range differs according to the mounted RFID module.
The setting range is from 0.0 to 24.0 dBm.
MCS
Enable or disable the Multi vendor Chip-based Serialization.
• ENABLE: Enable the Multi vendor Chip-based Serialization.
• DISABLE: Disable the Multi vendor Chip-based Serialization.
LOG
Enable or disable the log function to record the RFID data.
The log data can record up to100 tags of information.
• ENABLE: Enable the log function to record the RFID data.
• DISABLE: Disable the log function to record the RFID data.
LOG Data
Set the data to be recorded in the log when LOG is enabled.
• EPC and TID: Store the EPC and TID data.
• EPC: Store the EPC data.
• TID: Store the TID data.
Pre-Encoded Tag
Enable or disable the pre-encoded tag.
• ENABLE: Enable the pre-encoded tag.
• DISABLE: Disable the pre-encoded tag.