6 Cleaning and Performing Printer Adjustments
7
Take a note of the GAP(R) value from the above procedure. This is the "Low" level
value for the Gap sensor.
Next, check the "High" level (voltage) of the Gap sensor.
8
Unlock the media feed and media sensor
assembly .
9
Physically place the label  resting over
the Gap sensor.
10
Press the media feed and media sensor
assembly  down to lock it.
To get the correct adjustment result, close the
media sensor assembly before performing the
adjustment.
11
Check the new GAP(R) value. This is the
"High" level value for the Gap sensor.
If the difference between the "High" and the "Low"
level values is 1.0 V or more, then the adjustment
has satisfied the criteria.
If the difference between the "High" and the "Low"
level values is less than 1.0 V, repeat the procedure
from steps 3 through 11.
Criteria for Adjustment:
Low level (liner portion):
High level (label portion) - Low level:
12
Press the
screen.
Note
If you are having difficulties in adjusting the sensor level properly, clean the media sensor portion. If the
problem persists, contact your SATO reseller or technical support center to replace the media sensor.
13
Press the
SLICE LEVEL and then press the
ENTER button.
The slice level can be set to 0.0 V, or from 0.3 V to
2.9 V. (adjustable in increments of 0.1 V)
If you set the SLICE LEVEL to 0.0 V, the printer sets
the slice level automatically.
262
S84-ex/S86-ex Operator Manual
ENTER button to confirm the setting and proceed to slice level adjustment
buttons to change the
/
1
2
≤ +1.0 V
≥ +1.0 V
Gap sensors
area
High level