HEAD CHECK
Specify the number of media between each head check.
The setting range is from 0000 to 9999.
The head check function is disabled when the value is set to 0000.
PROTOCOL
Set the SZPL communication protocol.
• NONE
• ACK
• ZEBRA
RS485 NETWK ID
Set the RS485 network ID.
The setting range is from 000 to 999.
The network is not in used when the ID is set to 000.
CONTROL HEADER
Set the control header character.
The setting range is from 000 (00H) to 255 (FFH).
COMMAND HEADER
Set the command header character.
The setting range is from 000 (00H) to 255 (FFH).