SATO S84ex Operator's Manual page 373

Hide thumbs Also See for S84ex:
Table of Contents

Advertisement

Item
Print
Print End
(PREND)
T1 < 150 ns
Rise or fall time (T1) of PREND signal is less than 150 ns. You have to consider the time when
outputting the signal from the connected devices.
• When the print start signal and reprint signal are output simultaneously, the print start signal is enabled
and the printer does not perform reprinting.
• The reprint signal is valid only from the time of the print operation end (QTY=0) until the next print data
reception. Other than that, the printer does not perform reprinting.
Timing Chart
TYPE 1
TYPE 2
TYPE 3
TYPE 4
T1