Tighten the bleed valve (5) to a torque of 4 Nm ±10% and then release the lever.
Repeat the above operation until the old fluid flows out completely. Then, with the bleed valve definitely
closed to the specified torque actuate repeatedly the lever until a pressure is detected in the brake system.
Warning
After draining the old fluid from the reservoir and while filling the system, always keep the fluid level above
the MIN mark to avoid any air bubbles in the circuit.