Refitting the secondary air system
Remove the previously inserted cloth from the duct.
Warning
Do not invert the positions of the covers and components of the two valves of the secondary air system.
Refer to the reference notches present on the secondary air system valve cover and on head cover.
If disassembled, refit the secondary air system valves following the procedure described below.
Fit the retaining screw (15) in the secondary air system base (14).
Working on the opposite side, install O-ring (16) as shown in the figure.
Position the secondary air system base on the cylinder head and apply indicated threadlocker to screw (15).
Tighten screw (15) to a torque of 15 Nm (Min. 13 - Max. 17).