7.10.6 Drum Cleaner Unit

7.10.6.1 Construction
Cleaning blade
Blade vibration unit
Separation claw
F-7-64
7.10.6.2 Removing the Cleaning Blade
1) Slide out the process unit.
2) Remove the screw [1], and detach the
reciprocating arm [2].
[1]
F-7-65
3) Disconnect the 2 connectors [1], and remove
the 5 screws [2]; then, lift the rear and push it in
to detach the cleaning blade together with the
mounting plate [3].
[2]
[1]
[1]
F-7-66
0010-8829
0010-8830
[2]
[3]
4) Remove the E-ring [1], and detach the pressure
plate [2] to detach the cleaning blade assembly
[3].
[1]
F-7-67
The pressure plate looks like the one used for the
GP600 Sires or iR8500 Series machines; howev-
er, it is a different part with a different parts
number. Do not use the wrong part.
5) Remove the blade vibration unit from the
cleaner blade unit.
6) Remove the 5 screws [1], and detach the blade
retaining plate [2] to detach the cleaning blade
[3].
[3]
F-7-68
7.10.6.3 Mounting the Cleaning Blade
See "Maintenance and Inspection".
7.10.6.4 Removing the Blade Vibrating
Unit
1) Remove the blade unit.
2) Disconnect the connector [1], and remove the
2 screws [2]; then, detach the blade vibrating
unit [3].
(The rear and front blade vibrating units may be
disassembled in the same way.)
([3])
F-7-69
Chapter 7
[2]
[3]
[1]
[2]
[2]
[1]
[3]
0010-8832
0010-8833