Relay Pcb; High-Voltage Transformer (Ac); Hv-Ac Pcb - Canon imageRUNNER 7095 Service Manual

Hide thumbs Also See for imageRUNNER 7095:
Table of Contents

Advertisement

Chapter 10
10.5.23.2 Removing the All Night Power
Supply PCB
1) Remove the all night power supply PCB [1].
- all connectors of PCB
- 4 screws [2]
[2]
[2]
F-10-74

10.5.24 Relay PCB

10.5.24.1 Removing the Relay PCB
1) Remove the left lower cover. (4 screws)
2) Disconnect the connector from the PCB; then,
remove the screw [1], and detach the relay PCB
[1] from the four PCB holders [2].
[2]
[2]
F-10-75
10-22
0010-9605
[1]
0010-9604
[1]
[2]
[2]

10.5.25 High-Voltage Transformer (AC)

10.5.25.1 Removing the High-Voltage
Transformer Assembly (AC)
1) Remove the rear cover.
2) Remove the HV-AC PCB together with its
mounting base.
- 2 connectors [2]
- 2 screws [3]
[3]
[1]
F-10-76
3) Disconnect the 3 connectors [1], and remove
the screw [2]; then, detach the high-voltage
transformer assembly (AC) [3].
[2]
[1]
[3]
F-10-77

10.5.26 HV-AC PCB

10.5.26.1 Removing the HV-AC PCB
1) Remove the rear cover.
2) Remove the HV-AC PCB [1].
- 2 connectors [2]
- 4 screws [3]
[3]
[1]
F-10-78
[2]
[3]
[1]
[2]
[3]
0010-9603
0010-9602