Reference:
Timing of Cleaning
[1] if the surface temperature of the fixing roller is 100 deg C or less when the control panel power switch
is turned on.
[2] when wire cleaning is executed in user mode.
[3] at the end of LSTR after making 2000 prints since previous wire cleaning
7.5.3.4 Others
SERVICE MODE:
- COPIER> ADJUST> HV-TR> PRE-TR (pre-transfer charging current output adjustment value input)
If the DC controller PCB has been replaced or the RAM on the DC controller PCB has been initialized,
enter the value indicated on the service label.
ERROR CODE:
- E068 (pre-transfer charging output error)
The presence of over-current has been detected (POST/SEP_ERR=1), possibly caused by leakage.
7.6 Drum Cleaner Unit
7.6.1 Outline
The following shows the components of the machine's drum cleaner unit:
The presence of a cake of toner on the cleaning blade inside the cleaner unit is likely to prevent normal
cleaning of the drum, and the machine uses 2 blade vibration units to prevent adhesion of toner. When
these units vibrate, the entire blade will vibrate to shake off the toner, thereby eliminating cleaning faults
otherwise caused by cakes of toner.
Blade vibration unit
Cleaning Blade
Magnet roller
Waste toner feeding screw
Blade vibration unit
Pre-exposure lamp
Separation claw
M1
Main motor
F-7-23
Cleaning Blade
Blade vibration unit
F-7-24
Toner
Chapter 7
0010-8058
0010-8059
7-17