Replacing The Control Panel Module (Hot-Swap Drive System); Figure 57. Removing Power Supply From The Server System; Figure 58. Installing Power Supply Into The Server System - Intel SR1560SF - Server System - 0 MB RAM Service Manual

Server system
Hide thumbs Also See for SR1560SF - Server System - 0 MB RAM:
Table of Contents

Advertisement

The power supply can be replaced if it fails or if one of the fans that is integrated into it
fails. To replace the power supply, use the following instructions.
1. Disconnect all power cables.
2. Lift the power supply to disengage it from the latch (see letter "A") and remove the
power supply by sliding it out (see letter "B").
3. Insert the replacement power supply module (see letter "A") until it clicks into
place behind the latch (see letter "B"). Reconnect all power cables.
Replacing the Control Panel Module (Hot-swap
Drive System)
Your server must be operated with a control panel installed.
Caution: The control panel is NOT hot-swappable. Before removing or replacing the control panel,
you must first take the server out of service, turn off all peripheral devices connected to
the system, turn off the system by pressing the power button, and unplug the AC power
cord from the system or wall outlet.
52
supply, re-connect all power cables
in step 1 above, and reconnect AC power cord.

Figure 57. Removing Power Supply from the Server System

supply, re-connect all power cables
in step 1 above, and reconnect AC power cord.

Figure 58. Installing Power Supply into the Server System

B
A
AF002358
A
B
AF002359
®
Intel
Server System SR1560SF Service Guide