Panasonic PN28160A Operation Manual page 76

Cli screens layer 2 switching hub
Hide thumbs Also See for PN28160A:
Table of Contents

Advertisement

<Configuration Example>
Overview: Configure the telnet connection so that the sessions are allowed only from
specific network addresses (192.168.1.1 to 192.168.1.254).
(1) Enable the access limitation from telnet.
(2) Add the network address 192.168.1.0 (subnet mask 255.255.255.0), as a
source address for telnet connections, to Entry No. 1.
M24eG> enable
M24eG# configure
(1)
M24eG(config)# telnet-server access-limitation enable
(2)
M24eG(config)# telnet-server 1 192.168.1.0 255.255.255.0
M24eG(config)# exit
M24eG#
Fig. 3-5-2-2 Example of configuring the telnet access limitation
76

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pn28240a

Table of Contents