Cleaning the Silicone Oil Pan
Be sure to remove the silicone
oil collecting in the oil pan [7]
(found under the web feed
roller).
Further, if silicone oil should
drip, be sure to wipe it clean.

4.2.2 Mounting the Fixing Web

Mount the fixing web by reversing the steps used to remove it.
1) Wind the web [2] around the web take-
up roller [1] two or three times while
making sure that the arm guide plate [3]
will be outside the take-up roller (when
attaching to the front).
At this time, check to make sure that the
area of contact with the roller is impreg-
nated with oil.
Check to make sure that the fix-
ing web is not askew and it is
not slack or wrinkled. In addi-
tion, be sure that the web is
wound and attached as shown.
COPYRIGHT © 2001 CANON INC.
2000 2000 2000 2000
CANON iR5000i/iR6000i REV.0 JUNE 2001
CHAPTER 6 FIXING SYSTEM
[7]
F06-402-04
[3]
F06-402-05
Take-up roller
Feed roller
F06-402-06
[1]
[2]
6-25 P