Checking The Charging Assemblies - Canon iR5000i Service Manual

Hide thumbs Also See for iR5000i:
Table of Contents

Advertisement

CHAPTER 3 INSTALLATION

2.6 Checking the Charging Assemblies

Step
1
Remove the two screws[1], and detach the
feeding assembly front cover (right)[2].
2
Remove the screw[3], and detach the metal
fixing[4]; then disconnect the connector[5].
While holding the front and the rear of the
transfer/separation charging assembly at the
same time, pull it to the front to detach in the
left upper direction.
Check the transfer/separation charging as-
sembly; if dirt or paper lint is found, clean
with alcohol.
Mount the transfer/separation charging as-
sembly.
Connect the connector, and fit the metal fix-
ing.
Do not bring the transfer/separation
charging assembly into contact with the
transfer guide to avoid cutting the gut
wire. Further, be sure that the solvent has
evaporated completely.
3
Mount the feeding assembly front cover
(right) with two screws, and insert the fixing/
feeding assembly into the machine.
4
Remove the screw from the door tape (door
stopper) of the front panel. (This is to keep
the hopper open, which otherwise may close
when the hopper is opened.)
3-14 S
Work
COPYRIGHT © 2001 CANON INC.
Checks/remarks
[4]
2000 2000 2000 2000
CANON iR5000i/iR6000i REV.0 JUNE 2001
[1]
[2]
[5]
2
1
[3]

Advertisement