Canon iR5000i Service Manual page 849

Hide thumbs Also See for iR5000i:
Table of Contents

Advertisement

CHAPTER 6 SELF DIAGNOSIS
E713
Main Cause
The connector is not connected properly. The finisher accessories power
supply PCB is faulty. The finisher controller PCB is faulty. The DC control-
ler PCB is faulty.
Mode of
Detection
0000 The communications IC (IPC) on the finisher controller has gone
E717
Main Cause
The wiring is faulty (short circuit, open circuit). The copy data controller or
the remote diagnostic device is faulty. The main controller PCB is faulty.
Mode of
Detection
0001 The copy data controller or the NE controller is out of order or an
Caution
The error must be reset in service mode (COPIER>FUNCTION>
CLEAR>ERR).
E719
Main Cause
The wiring is faulty (short circuit, open circuit). The coin vendor is faulty.
The main controller PCB is faulty.
Mode of
Detection
0001 The communication between the coin vendor and the main control-
Caution
The error must be reset in service mode (COPIER>FUNCTION>
CLEAR>ERR).
E732
Main cause
The connector has poor contact. The reader controller PCB is faulty.
Mode of
Detection
0001 The main controller PCB has detected an error in the communica-
9999 in a printer mode, a read unit is detected by the main controller
6-10 T
out of order.
open circuit has been detected.
ler PCB has been interrupted.
tion between the reader controller PCB and the main controller
PCB.
PCB.
COPYRIGHT © 2001 CANON INC.
2000 2000 2000 2000
CANON iR5000i/iR6000i REV.0 JUNE 2001