CHAPTER 4 IMAGE FORMATION SYSTEM
8) Cut the excess of the charging wire with
nippers.
9) Tighten the mounting screw loosened in
step 3).
Keep tightening until the tension of the
grid wire is even.
Be sure to pay attention to avoid defor-
mation (slack) of the charging assembly
(as by tightening the mounting screw
found on the front of the left/right
shielding plate early).
10) Tighten the mounting screws loosened
in steps 1) and 2).
11) Wipe the grid wire with lint-free paper
moistened with alcohol.
1. Check to make sure that the
grid wire is free of bending
and twisting.
2. Be sure that the runs are laid
at equal intervals (i.e., the
wire is in the groove of the
block).
4-70 P