Table 158 SNMP Interface Traps (continued)
OPTION
OBJECT LABEL
DdmiRxPowerAlarmEventOn
DdmiVoltageAlarmEventOn
DdmiTxBiasAlarmEventOn
DdmiTemperatureWarnEven
tOn
DdmiTxPowerWarnEventOn
DdmiRxPowerWarnEventOn
DdmiVoltageWarnEventOn
DdmiTxBiasWarnEventOn
DdmiTemperatureAlarmEve
ntCleared
DdmiTxPowerAlarmEventCle
ared
DdmiRxPowerAlarmEventCl
eared
DdmiVoltageAlarmEventCle
ared
DdmiTxBiasAlarmEventClea
red
DdmiTemperatureWarnEven
tCleared
DdmiTxPowerWarnEventCle
ared
VES1724-56 User's Guide
OBJECT ID
1.3.6.1.4.1.890.1.5.12.46.45.2
7.2.1
1.3.6.1.4.1.890.1.5.12.46.45.2
7.2.1
1.3.6.1.4.1.890.1.5.12.46.45.2
7.2.1
1.3.6.1.4.1.890.1.5.12.46.45.2
7.2.1
1.3.6.1.4.1.890.1.5.12.46.45.2
7.2.1
1.3.6.1.4.1.890.1.5.12.46.45.2
7.2.1
1.3.6.1.4.1.890.1.5.12.46.45.2
7.2.1
1.3.6.1.4.1.890.1.5.12.46.45.2
7.2.1
1.3.6.1.4.1.890.1.5.12.46.45.2
7.2.2
1.3.6.1.4.1.890.1.5.12.46.45.2
7.2.2
1.3.6.1.4.1.890.1.5.12.46.45.2
7.2.2
1.3.6.1.4.1.890.1.5.12.46.45.2
7.2.2
1.3.6.1.4.1.890.1.5.12.46.45.2
7.2.2
1.3.6.1.4.1.890.1.5.12.46.45.2
7.2.2
1.3.6.1.4.1.890.1.5.12.46.45.2
7.2.2
Chapter 37 Access Control
DESCRIPTION
This trap is sent when a transceiver's
received optical power goes over the
"high alarm" threshold.
This trap is sent when a transceiver's
voltage goes over the "high alarm"
threshold.
This trap is sent when a transceiver's
laser bias current goes over the "high
alarm" threshold.
This trap is sent when a transceiver's
temperature goes over the "high
warning" threshold.
This trap is sent when a transceiver's
transmitted optical power goes over the
"high warning" threshold.
This trap is sent when a transceiver's
received optical power goes over the
"high warning" threshold.
This trap is sent when a transceiver's
voltage goes over the "high warning"
threshold.
This trap is sent when a transceiver's
laser bias current goes over the "high
warning" threshold.
This trap is sent when a transceiver's
temperature falls down below the high
alarm threshold and is back to the
normal range.
This trap is sent when a transceiver's
transmitted optical power falls down
below the high alarm threshold and is
back to the normal range.
This trap is sent when a transceiver's
received optical power falls down below
the high alarm threshold and is back to
the normal range.
This trap is sent when a transceiver's
voltage falls down below the high alarm
threshold and is back to the normal
range.
This trap is sent when a transceiver's
laser bias current falls down below the
high alarm threshold and is back to the
normal range.
This trap is sent when a transceiver's
temperature falls down below the high
warning threshold and is back to the
normal range.
This trap is sent when a transceiver's
transmitted optical power falls down
below the high warning threshold and is
back to the normal range.
339