ZyXEL Communications VES1724-56 User Manual page 337

24-port temperature-hardened vdsl2 box dslam
Hide thumbs Also See for VES1724-56:
Table of Contents

Advertisement

Table 157 SNMP System Traps (continued)
OPTION
OBJECT LABEL
fanspeed
FanSpeedEventOn
FanSpeedEventClear
temperature
TemperatureEventOn
TemperatureEventClear
voltage
VoltageEventOn
VoltageEventClear
rxCRC
rxCRCEventON
rxCRCEventClear
reset
UncontrolledResetEventOn
ControlledResetEventOn
RebootEvent
loopguard
LoopguardEventOn
externalarm
ExternalAlarmEventOn
ExternalAlarmEventClear
LPR
LPREventOn
VES1724-56 User's Guide
OBJECT ID
1.3.6.1.4.1.890.1.5.12.46.45.2.
1
1.3.6.1.4.1.890.1.5.12.46.45.2.
2
1.3.6.1.4.1.890.1.5.12.46.45.2.
1
1.3.6.1.4.1.890.1.5.12.46.45.2.
2
1.3.6.1.4.1.890.1.5.12.46.45.2.
1
1.3.6.1.4.1.890.1.5.12.46.45.2.
2
1.3.6.1.4.1.890.1.5.12.46.27.2.
1
1.3.6.1.4.1.890.1.5.12.46.27.2.
2
1.3.6.1.4.1.890.1.5.12.46.45.2.
1
1.3.6.1.4.1.890.1.5.12.46.45.2.
1
1.3.6.1.4.1.890.1.5.0.1
1.3.6.1.4.1.890.1.5.12.46.45.2.
2
1.3.6.1.4.1.890.1.5.12.46.45.2.
1
1.3.6.1.4.1.890.1.5.12.46.45.2.
2
1.3.6.1.4.1.890.1.5.12.46.27.2.
1
Chapter 37 Access Control
DESCRIPTION
This trap is sent when the fan speed goes
above or below the normal operating
range.
This trap is sent when the fan speed
returns to the normal operating range.
This trap is sent when the temperature
goes above or below the normal operating
range.
This trap is sent when the temperature
returns to the normal operating range.
This trap is sent when the voltage goes
above or below the normal operating
range.
This trap is sent when the voltage returns
to the normal operating range.
This trap is sent when the downlink port
receives more than 10000 rxCRC
messages within 10 seconds.
This trap is sent when the amount of
rxCRC messages the downlink port
receives within 10 seconds returns to the
normal number (less than 10000).
This trap is sent when the Switch
automatically resets.
This trap is sent when the Switch resets
by an administrator through a
management interface.
This trap is sent when the Switch reboots
by an administrator through a
management interface.
This trap is sent when loopguard shuts
down a port.
This trap is sent when the external alarm
is received.
This trap is sent when the external alarm
stops sending an alert.
This trap is sent when the system loses
power.
337