The device sends an alarm trap and generates a syslog entry when the thresholds of the alarm
profile are exceeded.
Figure 66 VDSL Line Alarm Profile Setup
The following table describes the labels in this screen.
Table 44 VDSL Line Alarm Profile Setup
LABEL
Name
VTUC
VTUR
15 Minute FECS
Threshold
15 Minute ES
Threshold
15 Minute SES
Threshold
15 Minute LOSS
Threshold
15 Minute UAS
Threshold
15 Minute LOFS
Threshold
15 Minute LPRS
Threshold
15 Minute
FailedFullInt
Threshold
VES1724-56 User's Guide
DESCRIPTION
Enter a descriptive name for identification purposes.
Configure the thresholds in this column for the Switch (VTUC).
Configure the thresholds in this column for CPE devices (VTUR).
Enter the number of Forward Error Correction Seconds (FECS) that are permitted to occur
within 15 minutes.
Enter the number of Errored Seconds (ES) that are permitted to occur within 15 minutes.
Enter the number of Severely Errored Seconds (SES) that are permitted to occur within 15
minutes.
Enter the number of Loss Of Signals Seconds (LOSS) that are permitted to occur within 15
minutes.
Enter the number of UnAvailable Seconds (UAS) that are permitted to occur within 15
minutes.
Enter the number of Loss Of Framing Seconds (LOFS) that are permitted to occur within
15 minutes.
Enter the number of times a Loss of PoweR Seconds (LPRS) is permitted to occur within 15
minutes.
Enter the number of times a full initialization is allowed to fail within 15 minutes.
Chapter 9 VDSL Setup