CAUSE
REMEDY
-
Generator
charge
light does
no.
Jlght
up
with
Ignition
key on
(Idling engine)
•
Burnt indicator
bulb
•
Fit new bulb
2
Discharged battery
2
Charge battery
from
an external electric source
3
Defective
battery
3
Replace
battery
4
Damaged
or disconnected
cables
4
Replace
or connect
cables
5
Defective regulator
5
Replace
regulator
6
Shorted positive
diode
of alternator
6
Have
alternator repaired in a specialized shop
7
Worn out brushes
7
Change brushes
S
Slip rings
oxidized
,
interruption
of
rotor
win-
S
Have
alternator repaired
di
ng
Generator
light stays lit at
higher
revs.
I
Conductor 0
+
/
61 grounded
•
Replace
conductor
or
refl1.ove ground
contact
2
Defective regulator
2
Replace regulator
3
Defective
rectifier,
dirty slip rings, direct
cur-
3
Have alternator
repai
red
;n
a qualified shop
rent in
conductor
OF
or
in rotor
winding
Generator light
Is lighted on engine stopped
bu'
sparkles or
darkens on running
engine
•
Contact
resistances in charge circuit
or in ca-
l
Eliminate the resistance to the contact
ble
to
indicator
light.
2
Defective
regulator
2
Replace regulator
3
Defective
alternator
3
Have
alternator repaired
Generator light flickers
1
Incorrect
calibration in
the
contact type
,e-
1
Replace regulator
gulator or burnt out
resistance
of
regulator.
24.3
REGULATOR
Model
- Main
features
Bosch AD
1/
14
N.
0.190.601
.009
Test
speed
4500
rpm.
Test
load
13
Amp.
Adjusti
ng
voltage
13.9
-14.8
V
24.4
RECTIFIER
Model
Bosch
14
V-22
AN.
0.197.002.003
24.5
STARTER MOTOR N. 0.001.157.016
(fig
.
188)
Ma in
features
Bosch OF 12
V
0.7
KW
Voltage
12
V
Output
0.7KW
Pinion
8
teeth
-
mod.
2.5
Pinion
rotation
coun terclockwise
Brush
pressure
800-900 grams
Minimum
brush length
11
.5
mm
(.435")
129