The valid frequency range varies according to the selected band.
Table 4-3:
B
AND
Ku-Band
C-Band
L-Band
S
YMBOL
The Symbol Rate parameter must be set according to the satellite transponder
symbol rate. The Symbol Rate value can be acquired from the satellite
transponder information or can be calculated, with the bit rate information.
29.818000 [Mbaud]
<01.000000 - 45.000000>
Available values range from 01.000000 to 45.000000 Mbaud.
N
OTE
It is important to input the accurate Symbol Rate down to the sixth digit after
the decimal point.
M
ODULATION
The Modulation
modulation method.
1
2
3
4
R
OLL
The Roll off menu is used for setting the receiver's roll-off factor value
according to the roll-off factor of the transmitted signal.
Page 4-22
Band Frequency Range
R
ATE
Symbol Rate
menu allows setting the PVR 6000 receiver to the relevant
Modulation
AUTOMATIC
DVBS-QPSK
DVBS-8PSK
DSNG-16QAM
-
OFF
M
F
INIMUM
REQUENCY
10.700000GHz
3.200000GHz
0.950000GHz
User Manual
Operation and Management
M
F
AXIMUM
REQUENCY
12.750000GHz
4.200000GHz
2.150000GHz
(Rev. 4.1/ SW v1.60/ December 2006)