I Nstallation I Nstructions; Site Preparation; Mechanical Rack Installation - Harmonic ProView PVR 6000 Series User Manual

Professional integrated receiver decoders
Table of Contents

Advertisement

2.3.
I
This section explains the mechanical installation of the rack and PVR 6000
device.

2.3.1. Site Preparation

When installing the PVR 6000 in a standard 19" rack, verify that the rack is fully
prepared for the installation. To facilitate easy access during installation and
maintenance, leave sufficient space behind the rack.
The PVR 6000 must be installed within 1.5m (5 feet) from an easily accessible
grounded AC outlet, capable of furnishing the required supply voltage as
detailed in Section 2.5.1.
The use of a UPS (Uninterrupted Power Supply) and an AVR (Automated Voltage
Regulation) is highly recommended to ensure uninterrupted operation.
Ensure that a qualified electrician has installed the main power supply in
accordance with local power authority regulations. All powering should be wired
with an earth leakage in accordance with local regulations.
TO AVOID ELECTROCUTION ENSURE THAT THE RACK HAS BEEN
CORRECTLY GROUNDED BEFORE SWITCHING ON THE PVR 6000 DEVICE.
WHEN REMOVING THE UNIT, REMOVE THE GROUNDED CONNECTION
ONLY AFTER THE UNIT IS SWITCHED OFF AND UNPLUGGED.

2.3.2. Mechanical Rack Installation

Due to its considerable weight, the device must be placed on a pair of rack-
slides, specially designed for this product (see Figure 2-1).
T
HE RACK
SINCE THEY ARE INTENDED TO CARRY THE DEVICE
DEVICE
IN DAMAGE TO THE RACK
Page 2-2
NSTALLATION
W
ARNING
C
AUTION
-
SLIDES MUST BE INSTALLED IN THE DEVICE
'
S MOUNTING BRACKETS FOR SUPPORTING THE DEVICE
,
DEVICE
I
NSTRUCTIONS
'
S DESIGNATED LOCATION WITHIN THE RACK
'
S WEIGHT
,
AND OTHER MOUNTED DEVICES
User Manual
Installation
. D
NOT
O
RELY ONLY ON THE
'
. D
S WEIGHT
OING SO MAY RESULT
.
(Rev. 4.1/ SW v1.60/ December 2006)
,