Table 4-2 lists the different bands, and their respective frequency ranges.
Table 4-2:
B
AND
L-Band
C-Band
Ku-Band
S
YMBOL
The
symbol rate of the received signal.
27.000000 [Mbaud]
<00.016000 – 45.000000>
Available values range from 00.016000 to 45.000000 Mbaud
N
OTE
The symbol rate must be set to match the exact symbol rate value used by the
satellite transponder.
M
ODULATION
The Modulation menu allows setting the PVR 6000 receiver to the relevant
modulation method.
DVBS-QPSK
1
DSNG-8PSK
2
DSNG-16QAM
3
DVBS2-N-QPSK
4
Band Frequency Designations
R
ATE
Symbol Rate
menu is used for adjusting the receiver's symbol rate to the
Symbol Rate
Modulation
F
REQUENCY
0.950000-2.150000GHz
3.200000-4.200000GHz
10.700000-12.750000GHz