Selecting Line1 displays the following screen:
23
<00 - 23>
The WSS signal can be inserted into a line between 0 and 23.
VI (V
The PVR 6000 supports AFD (Active Video Format Description) parsing, when
such data exists in the video e.s. – User Data, according to ETSI TS 101 154
Annex B. The AFD data is reinserted into VBI VI (Video Indexing) line 11, on 625
systems, according to SMPTE RP 186-1995 (only Class 1.1 "Information required
to display the signal, not including pan and scan" is currently supported).
Selecting VI (Video Index) displays the following screen:
Source
1
Line1
2
Selecting Source displays the following screen:
1
2
3
The available options are:
Line1 is a read-only parameter. VI data is always reinserted into line 11.
Page 4-92
Line1
I
IDEO
NDEX
VI (Video Index)
Source
DISABLE
E.S (EN-301-775)
VIDEO
DISABLE – VI data is not reinserted.
E.S.(EN-301-775) – will be supported in the future software releases
VIDEO – the PVR 6000 automatically detects the existing standard and
reinserts the VI data accordingly.
)