EST
The PVR 6000 can create a 1 kHz audio test signal, and output it through any of
its audio outputs for testing that audio output performance. The operator must
select the audio output to be tested and enable the creation of the test tone for
that output.
1
2
The available options are:
N
OTES
It is required to stop al IRD decoding before performing Audio Output testing.
Only Audio Outputs 1, 3, and 4 can currently be tested using the PVR 6000
internal 1 kHz test tone.
Page 4-108
T
ONE
Test Tone
DISABLE
1000 Hz
DISABLE – disables the test tone
1000 Hz – creates a 1 kHz audio signal and outputs it through this Audio
output