PVR 6000 Series
Professional Integrated Receiver Decoders
The available options are:
•
STREM PCR – The VCXO is synchronized to the program clock recovered
from the PCR data.
•
FIXED VALUE – The VCXO is running in free mode.
•
GENLOCK – Synchronizes the PVR 6000 according to MPEG Encoder
external video signal.
•
GENLOCK (LipSync) – Additional Genlock that Synchronizes the PVR 6000
according to the Video GenLock input. This feature ensures a range of
approximately 4mSec delta time between Audio/Video synchronization.
N
OTE
The VCXO is factory calibrated to a fixed 27 MHz clock.
Page 4-45