Option
Error Flag
2.7.3.3 Device Monitor Screen
The device monitor offers three options:
Easy monitor
Entry monitor
Forced on/off
Whenever you select a device on the screen, the following input screen appears:
You can use the
device type, device number, or display format button to display the input screen where you
can input device number or values.
Description
Displays the status of the special internal relays R9000 and R9002 to R9008. Dark error
flags are OFF.
and
button to scroll through the list of devices or directly press a
2.7 FP Monitor
85