GTWIN Reference Manual
Display Decimal Places
Select "On" to display digits after the decimal point and specify how many digits after the
decimal point you wish to see. Please remember that the digits used for the decimal places
will be subtracted from the total number of digits.
Display
5.5.2 Input Settings for Data Parts
This section explains the parameters on the "Input" tab in detail. Select "On" to display the
parameters.
If you want to allow the user to input values for devices such as a PLC with a
data part, the data part must be used in conjunction with a keyboard part (see p.
223) or a keyboard screen (see p. 115).
Startup Condition
This parameter activates the data part for data input. One or both of the parameters can be
selected.
Option
Functionality
Press
Pressing the data part on the base screen activates the data part. Then you can input data via
Setting
Number of Digits = 4
Display Decimal Places = On
Decimal Places = 2
5.5 Data Parts