GT Panel System Menu
The following device types are available:
Device type
DT
LD
SV
EV
FL
WGR
GDT
WX
WY
WR
WL
T
C
X
Y
R
L
For word devices, three display formats are available. Due to the limited screen size, the
display format has to be abbreviated.
Abbreviation
US1 (default)
S1
US2
S2
H1
H2
BIN
ASC
BC1
BC2
Easy monitor
Use the easy monitor to read or write values from a specified device. You can monitor both
word and bit devices.
86
Description
Data register (default)
Link register
Timer/counter set value
Timer/counter elapsed value
File register
Data register (GT internal)
Internal relay (GT internal)
External input
External output
Internal relay
Link relay
Timer
Counter
Input
Output
Internal special relay
Link relay
Format
Decimal (1 word, unsigned)
Decimal (1 word, signed)
Decimal (2 words, unsigned)
Decimal (2 words, signed)
Hexadecimal (1 word)
Hexadecimal (2 words)
Binary (1 word)
ASCII (1 word)
BCD (1 word)
BCD (2 words)
GTWIN Reference Manual