Figure 2-29. Enter Transmitter Channel Information
TX Calibration
The transmitter calibration (adjustment) function fixes errors in
incline in the self-leveling mechanism of the transmitter, applying an
offset to the transmitter. The transmitter must be in calibration mode
for this function and the Rover setup approximately 30 meters (100
feet) away. The height of the sensor must be at an angle less than 1° in
relation to the transmitter.
NOTICE
To begin a resection, tap TX Calibration on the Transmitters tab of
the transmitter setup dialog box. If needed, check the setup listed
on-screen (Figure 2-30 on page 2-22) and tap OK.
P/N 7010-0628
If the sensor experiences excessive movement
during any stage of the adjustment, an error
message will display. Press Cancel and stabilize the
Rover pole. Then press TX calibration again.
mmGPS Applications
2-21