SERVICE PROGRAM MODE
2.4 SP MODE 9–OUTPUT CHECK
– How to turn electrical components on/off –
1. Enter "9" by the numeral key, then press the Auto Image Density key.
2. Enter the desired number given in the following table.
3. Press the Start key to turn on the electrical component.
4. Press the Clear/Stop key to turn off the electrical component.
Number
1
Main Motor + Quenching Lamp
2
Charge Corona + Standard Image Grid
3
Charge Corona + Standard ID Sensor Grid
4
Charge Corona + Standard Vrp Grid
5
Transfer Corona
6
Separation Corona
8
Erase Lamp
9
ID Sensor LED
11
Toner Supply Clutch + Main Motor
12
Registration Clutch
13
1st Paper Feed Clutch
15
Relay Roller Clutch
18
Exhaust Blower Motor
19
Optics Cooling Fan (A152 copier only)
20
Exposure Lamp + Optics Cooling Fan (A152 copier only)
22
Charge Corona + Image Grid with correction + Transfer Corona + Separation
Corona
23
Charge Corona + ID Sensor Grid with correction + Transfer Corona +
Separation Corona
24
Charge Corona + Vrp Grid with correction + Transfer Corona + Separation
Corona
25
Charge Corona + Image Grid with correction
26
Charge Corona + ID Sensor Grid with correction
27
Charge Corona + Vrp Grid with correction
30–37
Development Bias Voltage in 40 volts steps starting at –120 volts
38
Development Bias Voltage = –500 volts
40–48
Grid Voltage in 60 volts steps starting at –400 volts