Control Panel; General Guidance - "Control Panel" Flow-Chart & Menu Options - Visonic PowerMaster 360 Installer's Manual

Table of Contents

Advertisement

4. PROGRAMMING

4.5 Control Panel

General Guidance – "Control Panel" Flow-Chart & Menu Options
4.5.1
The "CONTROL PANEL" menu enables you to configure and customize the operation of the control panel. The
"CONTROL PANEL" menu provides you with configurable parameters divided into several groups, each dealing with
certain aspects of the system operations as follows (see detailed list in Step 2 of the chart below):
Group
Description of Group Features and Parameters
Arming/Disarming
Contains configurable features and parameters related to Arming and Disarming of the
and Exit/Entry
system and the Exit and Entry procedures.
Procedures
Zone Behavior
Contains configurable features and parameters related to the functionality of the Zones.
Alarms &
Contains configurable features and parameters related to initiating, canceling and
Troubles
reporting of Alarm and Trouble events.
Sirens
Contains configurable features and parameters common to all sirens in the system.
User Interface
Contains configurable features and parameters related to the functionality of the panel's
audible and visual indications.
Jamming &
Contains configurable features and parameters related to detecting and reporting of RF
Supervision
Jamming and device Supervision (missing device) events.
Miscellaneous
Contains a variety of other configurable features and parameters related to the system.
To enter the "03.CONTROL PANEL" menu and to select and configure an option, proceed as follows:
Step 1
Select "CONTROL PANEL"
option
INSTALLER MODE
03.CONTROL PANEL
24
Step 2
Select the "Control Panel" Parameter you wish to configure
See
Arming &
4.5.2
Disarming
01:ENTRY DELAY1
02:ENTRY DELAY2
03:EXIT DELAY
04:EXIT MODE
05:QUICK ARM
06:BYPASS ARM
07:LATCHKEY ARM
08:DISARM OPTION
09:ARMING KEY
Zone
4.5.3
Behavior
21:SWINGER STOP
22:CROSS ZONING
See
Alarms &
4.5.4
Troubles
31:PANIC ALARM
32:DURESS ALARM
33:INACTIVE ALRT
34:TAMPER ALARM
35:AC FAIL REPRT
36:CONFIRM ALARM
37:ABORT TIME
38:CANCEL ALARM
39:ALARM RESET
40:ABORT FIRE T.
Sirens
4.5.5
44:SIREN TIME
45:STROBE TIME
D-305735 PowerMaster 360 Installer's Guide
See
User
4.5.6
Interface
53:MEMORY PROMPT
54:LOW-BAT ACK
56:SCREEN SAVER
Jamming and
4.5.7
Supervision
61:JAM DETECT
62:MISSING REPRT
63:NOT READY
64:MISS/JAM ALRM
65:SMOK FAST MIS
Miscellaneous
4.5.8
91:USER PERMIT
93:SOAK PERIOD
Section
4.5.2
4.5.3
4.5.4
4.5.5
4.5.6
4.5.7
4.5.8
Step 3
Configure
option
Go to the
indicated
group
section of
the
selected
option
When
done  to
Step 2

Hide quick links:

Advertisement

Table of Contents
loading