4. PowerMaster-30 G2 INSTALLATION

4.9 Connecting AC Power to the Control Panel

WARNING! DO NOT USE AN OUTLET CONTROLLED BY A WALL SWITCH.
Note: This equipment should be installed in accordance with Chapter 2 of the National Fire Alarm Code, ANSI/NFPA 72,
(National Fire Protection Association).
Connect the power cable and close the control panel as shown in Figure 4.9. The socket outlet shall be installed near
the equipment and shall be easily accessible.
PERFORM STEPS 1 & 2 ON A
WORKBENCH BEFORE THE MOUNTING
1. Thick cable entry: Pull out a desired
wiring plastic cap (1 of 4).
2. Extract cable clamp for use in the next
step.
1. Insert the power cable through the desired wiring
channel (A). Route it to the power supply unit (E) and
connect its 2 wires to the power supply terminal block
(F) with a screwdriver. Fasten the screws tightly.
Verify that the wires are properly fastened! Fasten the
power cable by its clamp (B or C) and close the safety
cover (D).
2. Connect the power supply output cable (G) to the
power connector (H) in the front panel.
24
POWER CABLE CLAMP EXTRACTION
POWER CONNECTION FOR INTERNAL POWER SUPPLY
A. Optional wiring channels
B. For thin cable
C. For thick cable (reversed clamp)
D. Safety cover
E. Power supply unit
F. Power supply terminal block
G. Power supply output cable
H. Power connector
(*) Do not route wiring in this area, to enable proper
closure of the control panel.